6000-100Ch5.fm Rev. D TimeVault™ User’s Manual 5-87
5
TimeVault-Generated Messages
5.1 Error Messages
5.1.1 ERROR 01 VALUE OUT OF RANGE
Meaning: You have entered a valid command, with an invalid parameter value.
Recovery Action: Re-enter the command, using a valid parameter.
5.1.2 ERROR 02 SYNTAX
Meaning: You have entered a valid command with a minor syntax error. The
NET Port network interface software has detected the error.
Recovery Action: Re-enter the command, using valid syntax.
5.1.3 ERROR: Invalid Command
Meaning: You have entered an invalid command.
Recovery Action: Consult the manual for the correct command and re-enter.
5.1.4 ERROR: Can’t create netdevice <NAME>
Meaning: TimeVault can not create the device needed to map the host to a drive.
Recovery Action: Restart the Unit. If this error message persists, contact Symmetricom
Technical Customer Service.
5.1.5 ERROR: Can’t set host <NAME> ip <ADDRESS>
Meaning: You have incorrectly entered a parameter, or there is no room
currently in the Host table for another IP Address.
Recovery Action: Verify correct parameter values. If correct, restart TimeVault
function. If this error message persists, contact Symmetricom
Technical Customer Service.